9185 sc ozone analyzer

Online Analyzer

Online Analyzer

9185-sc-臭氧分析仪

9185 sc ozone analyzer

Typical application Ozone analyzer is suitable for ozone disinfection monitoring in drinking water, sewage, industrial process water and pure water industries. Instrument features ● Ozone analyzer adopts selective membrane electrode; ● It is not disturbed by PH, chlorine, bromine, chlorine dioxide or hydrogen peroxide in the sample; ● The process of replacing the membrane takes only a few seconds; detection principle Ozone analyzer detection Principle: O3 decreases at the gold electrode (cathode): O3 + H2O + 2e-→ O2 + 2OH-silver reference electrode (anode): silver is oxidized to: Ag +, reacts with bromine ions in the electrolyte: 2Br-+ 2Ag → 2AgBr + 2e-O3 at the cathode
9185-sc-臭氧分析仪
Product description
Technical indicators
typical application
The ozone analyzer is suitable for ozone disinfection monitoring in drinking water, sewage, industrial process water and pure water industries.
 
Instrument characteristics
● Ozone analyzer adopts selective membrane electrode;
● No interference from PH, chlorine, bromine, chlorine dioxide or hydrogen peroxide in the sample;
● The process of replacing the membrane takes only a few seconds;
 
Detection principle
The detection principle of the ozone analyzer: O3 is reduced on the gold electrode (cathode): O3 + H2O + 2e-→ O2 + 2OH-
On the silver reference electrode (anode): silver is oxidized to: Ag +, reacts with bromide ion in the electrolyte: 2Br- + 2Ag → 2AgBr + 2e-
The amount of reduction of O3 on the cathode produces a current proportional to the concentration of O3.
Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table
Technical index
Measuring range 5ppb~20 ppm 
Accuracy ± 3% or ± 10ppb, whichever is greater
Sample flow 14 L/hr
Lower detection limit 5 ppb
Response time 90% ≤90 sec
Sample flow 200~250 mL/min
Ambient temperature 0~45°C
Sample temperature 2~45°C
Power consumption 1.5 W
Calibration interval February
Maintenance interval 6 months, typical maintenance is membrane replacement, electrolyte;
Installation method Panel installation;
Injection connection 1/4-in. O.D.
Drain connection 1/2-in. I.D.
Alarm Output IP 66 (NEMA 4X)

 

Previous
Next
Customer message
 Fuguang

Mainly engaged in the distribution of environmental monitoring instruments and meters, as well as the integration and operation and maintenance of environmental monitoring systems; Research and development, production, and sales of environmental monitoring instruments;

Copyright ©2023 Fuzhou Fuguang Water Science&Technology    闽ICP备12013341号-2  Powered by saa 

 Fuguang

Follow Fuguang Water

 Fuguang

Official Taobao Store

Fuzhou Fuguang Water Science&Technology Co.,Ltd

闽ICP备12013341号-2  Powered by saa