FUGUANG

Hotline:400-668-8627丨MALL中文

1 1
Your location:
Homepage
/
/
/
HACH BIOTECTOR B3500c TOC (Total Organic Carbon) Analyzer

Online Analyzer

Online Analyzer

HACH-BIOTECTOR-B3500c-TOC(总有机碳)分析仪-(1)
HACH-BIOTECTOR-B3500c-TOC(总有机碳)分析仪

HACH BIOTECTOR B3500c TOC (Total Organic Carbon) Analyzer

In the TOC analysis operation, the patented technology is used to ensure the longest uptime and the highest reliability. Only 6 months of regular maintenance is required to achieve dual-channel sample monitoring. The design is compact and the space is small. Uptime and lowest operating cost. TOC monitoring the whole process of worry-free B3500c is equipped with a patented second-level advanced oxidation technology system, which can ensure the maximum reliability of the instrument and the longest uptime, while also taking into account the accuracy. Replenish reagents and replace tubes at the lowest cost of ownership
HACH-BIOTECTOR-B3500c-TOC(总有机碳)分析仪-(1)
HACH-BIOTECTOR-B3500c-TOC(总有机碳)分析仪
Product description
Technical indicators
To ensure the longest uptime and highest reliability in TOC analysis
 
Using patented technology, only need to perform regular maintenance every 6 months, to achieve dual-channel sample monitoring, compact design, small footprint, Hach BioTector B3500c can guarantee 99.8% uptime and lowest operating costs.
 
TOC monitoring hassle-free
 
The B3500c is equipped with a patented two-stage advanced oxidation technology system, which can ensure the maximum reliability of the instrument and the longest uptime, while also allowing for accuracy.
 
Minimum cost of ownership
 
Reagents can be replenished and the tubes can be replaced, and only need to be calibrated twice a year, Hach BioTector B3500c ensures customers have the lowest operating costs.
 
Small footprint = space saving
 
The design is compact and takes up less space. First, it can save the wall area to the greatest extent for installing other instruments.
 
Low reagent consumption
 
Only need to replenish reagents once every six months, compared with other instruments that require reagents to be replaced once a week or once a month, it can save you maintenance costs and achieve cost control.
 
One instrument suitable for multiple channels
 
With the ability to monitor dual-channel samples at the same time, eliminating the double cost of requiring two analyzers.
 
Small footprint = space saving
 
The design is compact and takes up less space. First, it can save the wall area to the greatest extent for installing other instruments.
 
One instrument suitable for multiple channels
 
With the ability to monitor dual-channel samples at the same time, eliminating the double cost of requiring two analyzers.
 
Principle of operation
 
TIC
 
Acid is added to lower the pH, so that the inorganic carbon is purged out as CO2. The purpose of detecting total inorganic carbon (TIC) is to ensure that it is not brought into the TOC.
 
Oxidation
 
BioTector's patented oxidation method (TSAO) is used to achieve complete and complete oxidation of the sample, including the conversion of organic carbon to CO2. TSAO uses hydroxyl radicals generated by sodium hydroxide combined with oxygen passing through an ozone generator as an oxidant.
 
TOC
 
In order to remove CO2 generated by oxidation, the pH of the sample needs to be lowered again. CO2 is purged out and measured by a specially developed NDIR CO2 analyzer. The result is shown as total organic carbon (TOC).
 

sizeSide view


top view

 


Panel details

Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table
Technical index
Ambient temperature 0 to 45 ºC (41 to 113 ºF)
Range 0-25 mg / L C (equipped with over-standard tracking function) Full over-standard tracking concentration range up to 100 mgC / L
Chloride tolerance range Up to 30%
Multi-channel measurement Can measure up to two channels, and can randomly take
communication Modbus®, PROFIBUS, Ethernet (Modbus is a registered trademark of Gould Inc.)
circulation time Normally 5 minutes and 30 seconds
parameter Measure TOC, TIC, TC and VOC
data storage
First 9999 response data
Top 99 error messages
Oxidation method Patented Advanced Secondary Oxidation Method (TSAO) using hydroxyl radicals
the size of granule Max. 100 μm
Range selection  Automatic or manual range selection
size  29.5 in x 19.7 in x 12.6 in
(Height x width x depth) 750 mm x 500 mm x 320 mm
Power requirements (voltage) 115/220 VAC
Display High contrast 40 × 16 LED backlit LCD display
Repeatability ± 3% of reading or ± .03 mg / L (30 ppb), whichever is greater
EExp / explosion-proof area North American Standard Certificate available (I Level 2 Zone 2)
Sample inlet temperature 0 to 60 oC (36 to 140oF)
Over-standard tracking Completely exceed the standard tracking up to 100 mgC / L
Maintenance cycle Maintenance every 6 months
humidity 5 to 85%, no condensation
User interface description Microcontroller with membrane keyboard
Language English, Spanish, French, other languages on request
Detection method Determination of CO2 by infrared measurement after oxidation
weight 46 kg (101.41 lbs)

 

Customer message
 Fuguang

Mainly engaged in the distribution of environmental monitoring instruments and meters, as well as the integration and operation and maintenance of environmental monitoring systems; Research and development, production, and sales of environmental monitoring instruments;

Copyright ©2023 Fuzhou Fuguang Water Science&Technology    闽ICP备12013341号-2  Powered by saa 

 Fuguang

Follow Fuguang Water

 Fuguang

Official Taobao Store

Fuzhou Fuguang Water Science&Technology Co.,Ltd

闽ICP备12013341号-2  Powered by saa