FUGUANG

FUGUANG

Online Analyzer

Online Analyzer
 ${ele.title}
 ${ele.title}

9187SC Chlorine Dioxide Detector

Product description
Parameters
Technical indicators

Product Overview:

The 9187 SC chlorine dioxide detector uses a selective membrane sensor for online chlorine dioxide measurement, featuring a wide range and low detection limit. It comes with a built-in temperature probe for temperature compensation. It is an online chlorine dioxide analyzer with strong anti-interference resistance, accurate measurement, and low maintenance requirements.

 

Working Principle:

The electrolyte and permeation membrane separate the electrolytic cell from the water sample, allowing chlorine dioxide to penetrate the membrane; There is a fixed potential difference between the two electrodes of the chlorine dioxide detector/meter, and the current generated is proportional to the concentration of chlorine dioxide;
At the cathode: ClO2 + 4H+ + 5e-→ Cl-+ 2H2O
On the anode: Cl- + Ag→ AgCl + e-
The selective membrane sensor of the 9187 sc chlorine dioxide detector features a temperature probe for temperature compensation.

 

Instrument Features:

  • Wide measurement range

    The 9187 sc chlorine dioxide detector uses a selective membrane sensor to measure chlorine dioxide, with a measurement range of 0.010 - 2 ppm (mg/L).

  • Temperature compensation

    The sensor of the 9187SC chlorine dioxide detector comes with a built-in temperature probe and can automatically compensate for temperature.

  • Accurate measurements

    Unaffected by chlorine, bromine, hydrogen peroxide, or ozone, reducing measurement errors, and data can be directly used for compliance reporting and process adjustments.

  • Minimal maintenance required

    The 9187 SC chlorine dioxide detector is generally calibrated every two months, with electrolyte and membrane replaced every six months, greatly reducing downtime and labor costs.

 

Application Areas:

The 9187 SC Chlorine Dioxide Detector is suitable for online monitoring of chlorine dioxide concentration in drinking water and industrial water disinfection and sterilization processes.

We could not find any corresponding parameters, please add them to the properties table
Technical Specifications
Measurement range: 0.010 - 2 ppm (mg/L) (Cl2O
Minimum detection limit: 10 ppb or 0.01 mg/L ClO2
Accuracy: 5% or ± 10 ppb ClO2
Response time: 90% is less than about 90 seconds
Sample flow rate: 200~250 mL/min
Storage temperature: -20~60℃
Operating temperature: 0~45℃
Sample temperature: 2~45℃
Calibration method: Laboratory comparison method
Calibration interval: One time / 2 months
Maintenance interval: Generally, replace the membrane and electrolyte every six months
Feed Link: 1/4-in. O.D.
Row Link: 1/2-in. I.D.
Protection level: IP-66/NEMA 4X
Instrument size: 270 x 250 mm
FUGUANG

Mailing Address: Building B, No. 168 Jinyan Road, Jianxin Town, Cangshan District, Fuzhou

Postal Code: 350007

Customer Service Hotline: 400-668-8627

Main Line/Fax: 0591-83305533/83305866

Email: fgwater@fuguang.com

FUGUANG

Follow us

FUGUANG

Taobao store

Copyright © Fuzhou Fuguang Water Science & Technology Co.,Ltd. All rights reserved | Powered by 233 Technology