QbD1200+ laboratory TOC analyzer

Product description
Parameters
Technical indicators

Product Overview:

The QbD1200+ laboratory TOC analyzer is a laboratory TOC detector that uses UV ultraviolet lamps + persulfate oxidation methods. It is specially designed for low-concentration samples, with a range between 0-100 ppm. This TOC detector is suitable for industries with low sample concentrations, such as pharmaceuticals, electric power, disease control, and tap water. This TOC tester offers advantages such as high repeatability, accurate measurement results, simple operation and easy maintenance, and low operating costs, perfectly addressing industry pain points such as poor repeatability, high operating costs, and complex maintenance in low-concentration TOC measurements, and complies with relevant pharmacopoeia and regulations.

 

Instrument Features:

  • High repeatability

    ● The QbD1200+ TOC detector reduces interference between measurements of different samples

    ● The QbD1200+ TOC analyzer delivers consistent measurements with good repeatability

  • Measurement results are accurate

    ● QbD1200+ online TOC detector can support continuous monitoring of multiple different sensors

    ● QbD1200+ TOC analyzer has self-test and on-demand diagnosis report at startup

    ● QbD1200+ TOC analyzer also has over-range recovery function

  • Easy to operate and maintain

    ● QbD1200 + TOC detector adopts 10.4 inch color touch screen, user interface is more intuitive

    ● QbD1200+ TOC analyzer has a wizard software interface, easy to operate

    ● QbD1200+ TOC detector comes with automatic adjustment of measurement range/dilution function, even if you do not know the sample concentration in advance, you can also complete the measurement.

    ● QbD1200+ Laboratory TOC Analyzer requires only one reagent to complete the corresponding measurement and analysis (self-prepared or purchased from Hash)

    ● QbD1200 + online TOC detector can support simple and convenient paperless function, and can export data to network shared directories managed by windows security policy.

  • Low operating costs

    ● The QbD1200+ TOC detector has low reagent costs

    ● No frequent maintenance required, only once a year is sufficient

    ● No need to equip a separate computer

  • Fast calibration saves time

    ● Calibration takes only 2 hours

    ● This TOC tester is equipped with automated system adaptability testing for USP and EP, as well as SDBS verification programs for JP

  • Comply with pharmacopoeia and regulations

    ● The QbD1200+ laboratory TOC analyzer complies with major global pharmacopoeia regulations, including: USP, JP, EP, IP, KP, ICH

    ● The QbD1200+TOC tester's simplified IQ / OQ / PQ certification procedures comply with ICH guidelines

    ● The QbD1200+TOC analyzer adopts a simple automated process and can be applied in the following areas:

    - USP/EP SST bulk water

    - USP SST sterile water

    - JP SDBS verification

    - KHP calibration compliant with JP standards

 

Target customer groups:

The QbD1200+TOC analyzer is mainly targeted at pharmaceutical companies' QC laboratories, drug R&D, drug testing institutes, power plants, CDC laboratories, third-party testing institutions, universities, and research institutes

 

Application Areas:

The QbD1200+TOC detector can be widely used in industries such as pharmaceuticals, electric power, disease control, and tap water, meeting the stringent requirements for water quality monitoring.

We could not find any corresponding parameters, please add them to the properties table
Technical Specifications
performance specifications
measurement range 0 ~ 100 ppm
precision <2% or 3ppb (whichever is greater).
accuracy ± 3%
calibration cycle about 2 hours
analysis time takes as fast as about 4 and a half minutes
inorganic carbon treatment
Do high-content inorganic carbon samples require additional inorganic carbon removal modules? no
Is dynamic endpoint detection used to ensure complete removal of inorganic carbon? Yes
system self-diagnostic function ensures data integrity
Will the instrument report TOC value if any of the following situations occur?
ultraviolet lamp intensity is too low no
insufficient carrier gas / storage tank empty no
reagent insufficient / bottle empty no
sample volume is insufficient / vial is empty no
reagent
reagent supply can be purchased or configured yourself
whether there is an option to prepare reagents yourself Yes
total number of reagents (acids, oxidizers, diluted water). one
measurement method and guarantee
oxidized UV (ultraviolet) lamp + persulfate
Confirm the UV lamp broadband silicate photodiode sensor
detector Digital NDIR
detector stability continuously verifies according to the reference value
pre-clear moisture from the detector Peltier cooler, using continuous current monitoring
the allocator module uses an injection pump, accurate to +/-1% of the volume
flow sensor dynamic fluid sensor (ensures accuracy in sample and reagent volume).
Carrier gas selection high-purity air, oxygen, or nitrogen
confirmation of carrier gas pressure dual-port pressure sensor
Closing of the carrier gas valve After measurement, the valve will close to avoid wasting gas
automatic range function Yes
analyze the pattern NPOC (cannot be purged organic carbon).
Data storage and retrieval
legal certification 21 CFR, all measurements in Part 11 are recorded in an encrypted database
paperless report Outputs reports via Ethernet to the network-shared directory managed by Windows security policies
IO (input/output). 3 USB ports, 1 Ethernet port
data export format PDF,CSV
user interface
monitor 10.4-inch high-resolution color touchscreen
External PC No external hardware required, embedded with the Windows 10 IoT Enterprise operating system
external keyboard/mouse optional, not required
easy operation An intuitive user interface that guides operators through measurement settings
technical specifications
calibration Automated process: 18-point calibration with KHP (5 concentrations, 3 repetitions each, 3 backgrounds).
calibration solution 5ppm C KHP (single 125ml bottle), dilute with reagent to concentrations of 1, 2, 3, 4, and 5 ppm
verifies testing/system adaptability Automated Process:
● USP SST bulk water
Blank, 500 ppb in C: sucrose, p-benzoquinone
● USP SST sterile water
Blank, 8 ppm in C: sucrose, p-benzoquinone
● JP-16<2.59> verify
Blank, 500ppb SDBS in C
comply with regulations
USP<643> (including sterile water SST), JP-16<2.59>, EP<2.2.44>, IP, CP, KP, US EPA 5310c Yes
21 CFR, Part 11 Yes
instrument-validated ICH guidelines, including:
Accuracy, precision, detection limits, quantitative limits, linearity, range, exclusivity, durability
Yes
automatic sampler
capacity 64 sampling bottles (40mL glass small bottles TOC).
style XYZ, separator perforation
sample plate material aluminum anodizing
general technical data
instrument size width 320 x depth 507 x height 410 mm
power supply 100-240 VAC,50/60 Hz,2A
weight 14 kilograms (31 pounds).
autosampler size width 366 x depth 537 x height 457 mm
power supply 100-240 VAC,47-63Hz
weight 21 kg (45 lbs).
operating temperature and humidity 5-35℃; Relative humidity reaches up to 90%, non-condensing
the unit used for reporting ug/L (ppb)
FUGUANG

Mailing Address: Building B, No. 168 Jinyan Road, Jianxin Town, Cangshan District, Fuzhou

Postal Code: 350007

Customer Service Hotline: 400-668-8627

Main Line/Fax: 0591-83305533/83305866

Email: fgwater@fuguang.com

FUGUANG

Follow us

FUGUANG

Taobao store

Copyright © Fuzhou Fuguang Water Science & Technology Co.,Ltd. All rights reserved | Powered by 233 Technology