ORBISPHERE K1100 cold light method dissolved oxygen sensor

Brand instruments

Brand Instrument

001
001-1
001-2

ORBISPHERE K1100 cold light method dissolved oxygen sensor

Product description: Hash ORBISPHEREK1100 dissolved oxygen sensor, measured by cold light method, quick response, low maintenance workload, only need to be calibrated once a year, using 410 controller, accuracy up to 0.8ppb, to ensure the accuracy of measurement. It is the first maintenance-free cold light method dissolved oxygen sensor used in power plants. It is used in conjunction with the ORBISPHERE410 controller to provide a new method for dissolved oxygen monitoring in power plants. The ORBISPHERE sensor has become the industry standard for dissolved oxygen measurement. Working principle: ORBISPHEREK1100 portable solvent
001
001-1
001-2
Product description
Technical indicators
product description:
 
Hash ORBISPHERE K1100 dissolved oxygen sensor, using cold light method to measure, quick response, low maintenance workload, only need to be calibrated once a year, using 410 controller, accuracy up to 0.8ppb, to ensure the accuracy of measurement. It is the first maintenance-free cold light method dissolved oxygen sensor for power plants. It is used in conjunction with ORBISPHERE 410 controller to provide a new method for dissolved oxygen monitoring in power plants. ORBISPHERE sensors have become the industry standard for dissolved oxygen measurement.
 
working principle:
 
ORBISPHERE K1100 Portable Dissolved Oxygen Analyzer uses cold light method for measurement.
 
Application industry:
 
ORBISPHERE K1100 Portable Dissolved Oxygen Analyzer is suitable for dissolved oxygen monitoring in power plants.

 

Product features and advantages:

● The K1100 dissolved oxygen sensor uses the cold light method, without the need to replace the membrane and electrolyte, which greatly reduces the maintenance workload and shortens the maintenance time.

● The response is rapid, and the measurement frequency of 2s / time can be maintained for 12 months and calibrated once a year.

● Using 410 controller, the accuracy is up to 0.8ppb, the measurement is accurate, and the process can be effectively controlled.

● The K1100 dissolved oxygen sensor is quick and easy to install and requires no special preparation.

Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table
Technical index
Water sample temperature: Range: -5 ~ 50 ℃
The temperature range that the sensor can withstand: -5~100℃
pressure: 1-20 bar abs
K-1100 sensor Range: 0-2000ppb
Reproducibility: ± 0.4ppb or 1%, whichever is greater
Repeatability: ± 0.8ppb or 2%, whichever is greater
Accuracy: ± 0.8ppb or 2%, whichever is greater
Detection limit: The lowest can reach 0.6ppb
Response time: 90% response time is less than 10 seconds (gas phase); less than 30 seconds in water
display resolution: 0.1ppb
calibration: Single point zero calibration
Calibration samples:
The standard sample is 99.999% nitrogen or similar oxygen-free gas
 
410 transmitter Certification: Electromagnetic compatibility standard: EN61326: 1997 / A1: 1998 / A2: 2001 / A3: 2003
Security level ETL: Composite UL61010-1 and CSA22.2 No. 61010-1
safety standard: EN61010-1: 2001 guidelines 73/23 / EEC
display: Monochromatic STN320 * 240 pixels, with LED backlight
Analog output: 3 intelligent 0 / 4-20mA (500 Ohms) output, can be linear programming or trilinear programming, can be configured to send diagnostic information or alarm information.
Relay:
Each channel has 3 measurement alarm relays (1A-30VAC or 0.5A-50VDC)
1 instrument alarm relay (1A-30VAC or 0.5A-50VDC)
Digital communication: RS485; Profibus DP (optional); Ethernet, USB client can download data from the computer; USB host can download data from the USB storage device.
data storage: Rolling buffer or one-time storage mode can store up to 1000 measured values and 1000 operator activities. The calibration records of the last 10 calibrations can be locked.
installation Installation device of process sensor: Stainless steel (316) or polyoxymethylene resin flow cell with 1/4 "or 6mm fittings
Ambient temperature: -5~50℃
humidity: Relative humidity is 0-95%, no condensation
power supply:
Universal power supply, 85-264VAC @ 50-60Hz, 25VA; 10-36VDC, 25W
 

 

Customer message
 Fuguang

Mainly engaged in the distribution of environmental monitoring instruments and meters, as well as the integration and operation and maintenance of environmental monitoring systems; Research and development, production, and sales of environmental monitoring instruments;

Copyright ©2023 Fuzhou Fuguang Water Science&Technology    闽ICP备12013341号-2  Powered by saa 

 Fuguang

Follow Fuguang Water

 Fuguang

Official Taobao Store

Fuzhou Fuguang Water Science&Technology Co.,Ltd

闽ICP备12013341号-2  Powered by saa